Choosing the Proper PVC Pipe & Fittings for the Job

Author: Ingrid

Jun. 30, 2025

Choosing the Proper PVC Pipe & Fittings for the Job

When your job requires PVC piping & fittings, it's important to identify the materials available at your disposal. PVC pipe fittings play an integral role when joining pipes to assist their operation, which means that buyers need to know their similarities (and differences) of each part so their system can work properly. So given the number of factors that can come into play when purchasing PVC fitting, we're going to walk you through the PVC piping process to save you time (and money) when tackling such a complex task.

Solid are exported all over the world and different industries with quality first. Our belief is to provide our customers with more and better high value-added products. Let's create a better future together.

PVC Sizing

When it comes to standard sizing, PVC fittings operate with a nominal system. The reason for this is so parts can be compatible with each other if the part is the same size. For example: Every 1" fitting will work with a 1" pipe. However, the OD (outer diameter) of the PVC pipe is bigger than its actual size, meaning that a 1" PVC pipe is going to have an outer diameter that is bigger than 1". So when looking at this sizing of fittings from a nominal size perspective, a 1" pipe will work with a 1" fitting, regardless if the piece is schedule 80 or 40. If a socket fitting possesses an opening greater than 1" across, it will have no problem fitting on a 1" pipe since the outer diameter is greater than 1" as well.

Another issue could arise if you plan on using non-PVC pipe with a PVC fitting. In situations as such, the nominal size isn't as important as the outer diameter of the pipe in use because the pipes and fitting will be compatible if the inner diameters remain the same. However, it should be mentioned that a 1" carbon steel pipe and a 1" PVC fitting may not operate properly since they do not operate with the same nominal size.

For additional information on sizing, view our detailed sizing and dimensions chart.

PVC Piping & Fittings Schedule 40 vs. 80

So if you happen to be a newbie to the PVC pipe fitting world, you'll notice a term called "schedule" will be thrown around quite often. Although you already have an established definition of the term, it doesn't carry the same meaning in the piping world. When it comes to PVC piping, this term schedule relates to the thickness of the pipe's walls. If you haven't caught on, this is the reason why Schedule 80 is a little more expensive than a comparable Schedule 40 pipe or fitting.

When it comes to outside diameter of both PVC fittings, they remain the same, with Schedule 80 Fittings utilizing thicker walls. When it comes to these pipe measuring standards, they were developed to adhere to a universal system that refers to PVC. With these different wall types being beneficial in certain situations, the ASTM created a schedule 40/80 system to classify both types.

The significant differences between these two fittings are:

  • Color
  • Use and application
  • Wall thickness
  • Water pressure rating
  • Additional information on buying the right piping: schedule 40 vs. schedule 80.

    Schedule 80 & Schedule 40 Fitting Use

    Since both types of fitting schedules have various uses, we're going to cover where each part shines given the scenario.

    1.) Handling Water Pressure

    When it comes to Schedule 40 or 80 PVC, both are used throughout the world. However, each has its own benefits. With schedule 40 PVC fittings, they're known to work best with applications utilizing low water pressure. With schedule 80 pipe fittings, they have thicker walls and can withstand higher levels of water pressure. This is the reason as to why schedule 80 PVC fittings are used for chemical and industrial applications.

    2.) Diameter & Sizing

    Sch 40 fittings and Sch 80 fittings carry the same outside diameter. This is mostly due to the fact that a schedule 80's additional wall thickness rests inside of the piping. Although a schedule 80 pipe might have a little more restriction to its flow, the parts can fit and operate together if needed. If you're installing Sch 40 parts into your piping system, it's important that the part will meet the needs of its application. Since your pipe line can only be as strong as the weakest joint or part, a Sch 40 part handling high pressure can cause serious damage to your system.

    3.) Fitting Colors

    Although such fittings can be found in many different colors, a schedule 80 fitting is oftentimes gray and schedule 40 fittings are usually white.

    4.) Application

    When it comes to the application of a schedule 80 PVC fitting or a schedule 40 PVC fitting, the decision rests on the type service it is going to provide. If you're attempting an irrigation or home repair project, a schedule 40 PVC might be the best choice. Schedule 80 is typically used in commercial or industrial applications that require higher ratings.

    PVC Pipe and PVC Fittings Explained

    Using and Understanding PVC Pipe and Fittings

    If you are even a little bit familiar with the irrigation industry, you probably already know there are no set industry standards as far as flexible poly tubing and fitting sizes are concerned. Although PVC is standardized, in its industry, it is still confusing when sizing or matching components with the pipe. It seems nothing is really the size it is named. In the manufacturing world, this is called nominal sizing. This guide was created to explain or clarify the correct sizing and matching of PVC pipe and fittings and the terminology used in this industry.

    A Little History About PVC

    First discovered way back in , it wasn’t until the early 20th century that PVC (polyvinyl chloride) was further developed into a more usable plasticized polymer. The rigid, often brittle polymer was combined with various additives to make it more flexible and easier to process. Very soon, it achieved widespread commercial use. 

    Today, PVC has two basic forms, rigid and flexible. Probably the most common use you can think of is PVC pipe, although it is also used in doors and windows, bottles, packaging, flooring and even in those little cards we use everyday instead of paper currency, just to name a few. Polyvinyl chloride (PVC) is the third most widely used plastic polymer in the world, with over half of that being used in making pipe and fittings for pipe that are used in our water and drainage systems.

    Some of the specifics that make rigid PVC so popular are availability, cost, density and strength, and its resistance to chemicals and alkalis.

    PVC Pipe Class and Schedule Ratings

    PVC pipe with a schedule (SCH) rating such as SCH 40 or SCH 80 is most common in plumbing and irrigation use. The larger the SCH number the stronger the pipe. While SCH 40; SCH 80; and SCH 120 are the same outside dimension for compatibility of fittings, the wall is thicker on SCH 80 & SCH 120 pipe. SCH 40 pipe is commonly used in pressure applications such as mainlines (pipes that are under constant pressure, located before the sprinkler zone valves) for sprinkler irrigation systems. SCH 40 pipe has relatively high PSI ratings. SCH 40 PVC pipe should never be threaded, just add an adapter fitting when threads are needed. Thicker walled SCH 80 is very common in threaded pipe nipples as the thicker wall allows for threads to be cut or molded into it. 

    Class (CL) ratings are based on the water pressure rating of the pipe. Available PVC classes include CL125 for 125 PSI; CL165 for 165 PSI; CL200 for 200 PSI; and CL315 for 315 PSI. Pressure ratings are usually given for water at 73°F. 

    Maximum Working Pressure for SCH 40 & SCH 80 PVC Pipe

    Nominal Pipe Size

    Max PSI SCH 40 Pipe

    Max PSI SCH 80 Pipe

    ½”

    600

    850

    ¾”

    480

    690

    1”

    450

    630

    1 ¼”

    370

    520

    1 ½”

    330

    470

    2”

    280

    400

    2 ½”

    300

    420

    3”

    260

    370

    The company is the world’s best pvc pipe joint supplier. We are your one-stop shop for all needs. Our staff are highly-specialized and will help you find the product you need.

    4”

    220

    320

    5”

    190

    N/A

    6”

    180

    280

    While the maximum operating temperature may be listed as 140°F, the service temperature rating is between 41° - 122°F continuous, and short or intermittent up to 140°F. The higher the temperature, the lower the pressure rating. See the chart for the de-rating factors at temperatures higher than 73°F.

    De-Rating Table

    Operating Temperature (°F)

    73

    80

    90

    100

    110

    120

    130

    140

    De-Rating Factor

    1.00

    0.88

    .075

    0.62

    0.51

    0.40

    0.31

    0.22

    To calculate this, take the working pressure of your PVC pipe SCH/class and size at 73° F and multiply by the de-rating factor nearest the operating temperature to get the maximum working pressure in your application.

    1” SCH 40 @ 73°F = 450 PSI so if operating temperature will be 110°F then the equation is:

    450 PSI × 0.51 = 229.5 PSI maximum working pressure

    Matching Your PVC Pipe and Fittings

    PVC pipe sizes are standardized nationally with iron pipe sizes and are identified by the nominal inside diameter (ID) pipe size. A common mistake is measuring the outside diameter of the PVC pipe which gives a much larger and incorrect size. The sizes, such as 1/2", 3/4", 1", etc... are referred to as "nominal" sizes, meaning "in name only" and does not necessarily match any exact measurement of the item. Here is a chart showing the nominal size, the actual outside diameter (OD), the minimum wall thickness and the average inside diameter (ID) for Schedule 40 PVC pipe.

    Once you confirm your PVC pipe size then selecting a fitting is easy, just match the nominal pipe size to the corresponding fitting size. 

    To recap, the most important thing to remember when working with PVC pipe and fittings is how the nominal size is noted. A 1" fitting will fit on a 1" pipe. This is true for both schedule 40 or 80. So, while a 1" socket fitting has an opening wider than 1" across, it will fit on a 1" pipe because the outside diameter of that pipe is also greater than 1".

    PVC Fitting Connections

    Schedule 40 PVC pipe does not have threaded ends so a slip fitting is needed to join sections of pipe together. Slip fittings will slip right on the PVC pipe and may seem tight, but will not hold water. The connection must be sealed. For a leak-proof seal on a slip fitting, you will need both PVC primer and PVC cement. The primer softens the inside of the fitting, preparing it to bond, while the cement bonds the two pieces together tight. 

    As an easy alternative to the hassle of primer and cement, HydroRain offers PVC-Lock fittings that are a simple push-fit style that do not require gluing for a leak-proof seal. Another advantage of PVCL is the fittings are removable and reusable. A size specific special release tool is required for removal. Here is a link to our selection of PVC-Lock Fittings.

    Another alternative, to creating connections that can be taken apart, is PVC threaded fittings. Keep in mind that threaded fittings are a weak point in any piping system and the working pressure is reduced by 50% when a threaded connection is used. Proper technique is required for a secure leakproof connection. Many manufacturers have differing recommendations for using any chemical aid when joining plastic threaded components. Chemicals, such as teflon and pipe dope can degrade the plastic and increase risk of premature failure. We suggest following manufacturers recommendations. The leak-proof seal of a male and female threaded PVC connection can be made using a thread sealant compatible with the material. The sealant is applied around the male (outside) threads, then the two (male and female fittings) are screwed together, finger tight, then one to two more turns at most. Over tightening can cause stress cracks that will fail!

    Here is a list of some of the common terminology used in describing PVC fittings.

    Slip refers to a fitting with no threads that slips over the pipe and requires primer and glue (solvent and cement) to create a leak proof seal.

    Socket (SOC) is the equivalent of a female end and slips over the PVC pipe of same size.

    Spigot (SPG) is the equivalent of a male end and fits into a socket end of the named size. PVC pipe has spigot ends and requires socket fittings to join.

    FPT or FIPT refers to a female pipe threaded connection. This means the threads are on the inside of the fitting. Connection is to a male pipe thread fitting.

    MPT or MIPT refers to male pipe threaded connection with threads on the outside of the fitting. Connection is to a female pipe threaded connection.

    Coupler, Coupling, or Union is a simple straight fitting used to join or “couple” two parts together. Couplers can be slip or female threads or a combination of the two, joining pipe to pipe, pipe to fitting or fitting to fitting. The union coupler has threaded tightening rings or collars on one or both ends for easy installation or removal of the connected parts.

    Tee is just what it sounds like, a “T” shaped fitting to connect parts in three different directions with two being a straight line and one creating an angle (usually 90 degree). Tee fittings can have slip or threaded connections.

    Elbow is used to make a turn in your line, most often found in 90 and 45 degree angles. Others may be available but much less common. Available in slip or threaded connections.

    Cross is also just like it sounds. It is used to join four pipes at four 90 degree angles. Usually found with slip connections.

    Adapter is a fitting with different connection types. Used to adapt from one type of part to another. Slip to a threaded connection or pipe thread to hose thread.

    Bushing is similar to an adapter, but is mainly used to join pipes of two different sizes together. Usually threaded or spigot. 

    Cap or End Cap closes the end of your pipe. A cap is a socket or female fitting.

    Plug has the same purpose as the cap but it is a spigot or male fitting. Most common with threads for plugging or closing a fitting.

    Want more information on ductile iron universal coupling? Feel free to contact us.

    64

    0

    Comments

    Please Join Us to post.

    0/2000

    All Comments ( 0 )

    Guest Posts

    If you are interested in sending in a Guest Blogger Submission,welcome to write for us!

    Your Name: (required)

    Your Email: (required)

    Subject:

    Your Message: (required)